beautypg.com

MITSUBISHI ELECTRIC FR-S520E User Manual

Page 73

background image

63

Function (Parameter) list

2

F

UNCT

IO

NS

P

a

ra

me

te

r L

ist

Communication Parameters

Func

tion

Parame-

ter

Indica-

tion

Name

Setting Range

Minimum

Setting

Incre-

ments

Factory

Setting

Refer

To:

Cus-

tomer

Setting

Co

mmu

n

ic

a

tio

n

Pa

ra

me

te

rs

n1 (331)

Communication
station number

0 to 31: Specify

the station
number of the
inverter.

1

0

137

n2 (332)

Communication
speed

48: 4800bps,
96: 9600bps,
192: 19200bps

1

192

137

n3 (333)

Stop bit length

0, 1: (Data length 8),
10, 11: (Data

length 7)

1

1

137

n4 (334)

Parity check
presence/
absence

0: Absent,
1: With odd parity

check,

2: With even

parity check

1

2

137

n5 (335)

Number of
communication
retries

0 to 10, - - -

1

1

137

n6 (336)

Communication
check time
interval

0 to 999s, - - -

0.1s

- - -

137

n7 (337)

Waiting time
setting

0 to 150ms, - - -

1

- - -

137

n8 (338)

Operation
command source

0: Command

source is
computer,

1: Command

source is
external
terminal

1

0

152

n9 (339)

Speed command
source

0: Command

sourse is
computer,

1: Command

source is
external
terminal

1

0

152

n10

(340)

Link startup
mode selection

0: As set in Pr. 79.
1: Started in

computer link
operation mode.

1

0

153

n11

(341)

CR/LF selection

0: Without CR/LF,
1: With CR,

without LF

2: With CR/LF

1

1

137

n12

(342)

E

2

PROM write

selection

0: Write to RAM

and E

2

PROM

1: Write to RAM

only

1

0

155

This manual is related to the following products: