MITSUBISHI ELECTRIC FR-S520E User Manual
Page 72
62
Function (Parameter) list
P
a
ra
me
te
r L
ist
Calibration parameters
* Factory settings may differ because of calibration parameters.
Func-
tion
Parame-
ters
Indi-
cation
Name
Setting Range
Minimum
Setting
Incre-
ments
Factory
Setting
Refer
To:
Cus-
tomer
Setting
Ca
lib
ra
tio
n
p
a
ra
me
te
rs
C1 (900)
FM terminal
calibration
C2 (902)
Frequency
setting voltage
bias frequency
0 to 60Hz
0.1Hz
0Hz
C3 (902)
Frequency setting
voltage bias
0 to 300%
0.1%
0% (*)
C4 (903)
Frequency setting
voltage gain
0 to 300%
0.1%
96%
(*)
C5 (904)
Frequency
setting current
bias frequency
0 to 60Hz
0.1Hz
0Hz
C6 (904)
Frequency setting
current bias
0 to 300%
0.1%
20% (*)
C7 (905)
Frequency setting
current gain
0 to 300%
0.1%
100%
(*)
C8 (269)
Parameter set by manufacturer. Do not set.
Cle
a
r p
a
ra
me
te
rs
CLr
Parameter clear
0: Not executed
1: Parameter clear
10: All clear
1
0
ECL
Alarm history
clear
0: Not cleared,
1: Alarm history
clear
1
0