MITSUBISHI ELECTRIC FR-S520E User Manual

Page 72

background image

62

Function (Parameter) list

P

a

ra

me

te

r L

ist

Calibration parameters

* Factory settings may differ because of calibration parameters.

Func-

tion

Parame-

ters

Indi-

cation

Name

Setting Range

Minimum

Setting

Incre-

ments

Factory

Setting

Refer

To:

Cus-

tomer

Setting

Ca

lib

ra

tio

n

p

a

ra

me

te

rs

C1 (900)

FM terminal
calibration







131

C2 (902)

Frequency
setting voltage
bias frequency

0 to 60Hz

0.1Hz

0Hz

86

C3 (902)

Frequency setting
voltage bias

0 to 300%

0.1%

0% (*)

86

C4 (903)

Frequency setting
voltage gain

0 to 300%

0.1%

96%

(*)

86

C5 (904)

Frequency
setting current
bias frequency

0 to 60Hz

0.1Hz

0Hz

86

C6 (904)

Frequency setting
current bias

0 to 300%

0.1%

20% (*)

86

C7 (905)

Frequency setting
current gain

0 to 300%

0.1%

100%

(*)

86

C8 (269)

Parameter set by manufacturer. Do not set.

Cle

a

r p

a

ra

me

te

rs

CLr

Parameter clear

0: Not executed
1: Parameter clear
10: All clear

1

0

134

ECL

Alarm history
clear

0: Not cleared,
1: Alarm history

clear

1

0

134