10 jog operation (pr.15 , pr.16 ), 11 run key rotation direction selection (pr.17 ), 11 r u n key rotation direction selection (pr.17 ) – MITSUBISHI ELECTRIC FR-S520E User Manual
Page 88
78
Explanation of functions (parameters)
2.3.10 Jog operation (Pr.15
, Pr.16
)
Set the frequency and acceleration/deceleration time for jog operation.
2.3.11
R U N
key rotation direction selection (Pr.17
)
Refer to
(page 69)
Refer to
,
(page 71)
To start/stop jog operation in the
external operation mode, choose the
jog operation function in input terminal
function selection, turn on the jog
signal, and turn on/off the start signal
(STF, STR).
You can choose the jog operation
mode from the parameter unit (FR-
PU04) and perform jog operation
using
the
or .
(Can be read as the basic parameters when the FR-PU04 is connected.)
Parameter
Name
Factory Setting Setting Range
Remarks
15
Jog frequency
5Hz
0 to 120Hz
Setting is enabled when
Pr. 30 = "1".
16
Jog acceleration/
deceleration time
0.5s
0 to 999s
CAUTION
•In S-shaped acceleration/deceleration pattern A, the acceleration/deceleration
time is the period of time required to reach Pr. 3 "base frequency", not Pr. 20
"acceleration/deceleration reference frequency".
•The acceleration time and deceleration time cannot be set separately for jog
operation.
•The Pr. 15 "Jog frequency" value should be equal to or higher than the Pr. 13
"starting frequency" setting.
•Assign the jog signal using any of Pr. 60 to Pr. 63 (input terminal function
selection).
♦Related parameters♦
•
Assignment of jog signal to terminal
⇒
Pr. 60 to Pr. 63 (input terminal function selection)
(refer to page 102)
•
Acceleration/deceleration pattern S-shaped acceleration/deceleration A
⇒
Pr. 29 "acceleration/deceleration pattern" (refer to page 83)
Used to choose the direction of rotation by operating the
key of the operation
panel.
Parameter
Name
Factory
Setting
Setting
Range
Remarks
17
RUN key rotation
direction selection
0
0, 1
0: Forward rotation
1: Reverse rotation
Setting is enabled
when Pr. 30 = "1".
FWD
REV
Output frequency (Hz)
ON
Pr.20
Forward
rotation
Pr.16
Jog frequency
setting range
Pr.15
JOG signal
STF signal
ON
RUN
RUN