33
Input terminals
1
WI
RING
*When using the REX signal, an external command cannot be used to make a
reverse rotation start.
Multi-Speed Operation Connection Example
Multi-Speed Setting
Speed
Terminal Input
Parameter
Set Frequency
Range
Remarks
REX-
SD*
RH-
SD
RM-
SD
RL-
SD*
Speed 1
(high
speed)
OFF
OFF OFF
Pr. 4
0 to 120Hz
Speed 2
(middle
speed)
OFF OFF
OFF
Pr. 5
0 to 120Hz
Speed 3
(low
speed)
OFF OFF OFF
Pr. 6
0 to 120Hz
Speed 4 OFF OFF
Pr. 24
0 to 120Hz, - - -
Pr. 6 setting when Pr. 24="- - -"
Speed 5 OFF
OFF
Pr. 25
Pr. 6 setting when Pr. 25="- - -"
Speed 6 OFF
OFF
Pr. 26
Pr. 5 setting when Pr. 26="- - -"
Speed 7 OFF
Pr. 27
Pr. 6 setting when Pr. 27="- - -"
Speed 8
OFF OFF OFF
Pr. 80
0Hz when Pr. 80="- - -"
Speed 9
OFF OFF
Pr. 81
Pr. 6 setting when Pr. 81="- - -"
Speed 10
OFF
OFF
Pr. 82
Pr. 5 setting when Pr. 82="- - -"
Speed 11
OFF
Pr. 83
Pr. 6 setting when Pr. 83="- - -"
Speed 12
OFF OFF
Pr. 84
Pr. 4 setting when Pr. 84="- - -"
Speed 13
OFF
Pr. 85
Pr. 6 setting when Pr. 85="- - -"
Speed 14
OFF
Pr. 86
Pr. 5 setting when Pr. 86="- - -"
Speed 15
Pr. 87
Pr. 6 setting when Pr. 87="- - -"
External
setting
OFF OFF OFF OFF
Frequency
setting
potentiometer
0 to max. setting
REMARKS
*1. When the frequency setting potentiometer is connected, the input signal of the frequency
setting potentiometer is ignored if the multi-speed select signal is switched on. (This also
applies to the 4 to 20mA input signal.)
*2. For a reverse rotation start, set Pr. 63 to "- - -" (factory setting) to make the STR signal of
terminal STR valid.
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
10
2
5
Power supply
Forward rotation
Multi-speed
selection
Frequency
setting
potentiometer
Inverter
U
V
W
STF
REX
RH
RM
RL
IM
Motor
*2
*1
R
S
T
SD