53

Function (Parameter) list

2

F

UNCT

IO

NS

P

a

ra

me

te

r L

ist

The extended function parameters are made valid by setting "1" in Pr. 30 "extended
function display selection". (For more detailed information on the way to set Pr. 30,
refer to the instruction manual (basic).)

Func-

tion

Para-

meter

Indica-

tion

Name

Setting Range

Minimum

Setting

Increments

Factory

Setting

Refer

To:

Cus-

tomer

Setting

S

tan

da

rd

o

per

at

io

n

f

u

n

c

ti

o

n

s

Parameters 0 to 9 are basic function parameters.

10

DC injection
brake
operation
frequency

0 to 120Hz

0.1Hz

3Hz

75

11

DC injection
brake
operation time

0 to 10s

0.1s

0.5s

75

12

DC injection
brake voltage

0 to 15%

0.1%

6%

75

13

Starting
frequency

0 to 60Hz

0.1Hz

0.5Hz

76

14

Load pattern
selection

0: For constant-torque

loads,

1: For variable-torque

loads,

2: For vertical lift loads,
3: For vertical lift loads

1

0

77

15

Jog frequency 0 to 120Hz

0.1Hz

5Hz

78

16

Jog
acceleration/
deceleration
time

0 to 999s

0.1s

0.5s

78

17

RUN key
rotation
direction
selection

0: Forward rotation,
1: Reverse rotation

1

0

78

19

Base frequency
voltage

0 to 800V, 888, - - -

1V

- - -

69

20

Acceleration/
deceleration
reference
frequency

1 to 120Hz

0.1Hz

60Hz

71

21

Stall
prevention
function
selection

0 to 31, 100

1

0

79

22

Stall
prevention
operation
level

0 to 200%

1%

150%

81

23

Stall
prevention
operation level
compensation
factor at
double speed

0 to 200%, - - -

1%

- - -

81

This manual is related to the following products: