142

Communication parameters

5) Waiting time

Specify the waiting time between the receipt of data at the inverter from the
computer and the transmission of reply data. Set the waiting time in accordance
with the response time of the computer between 0 and 150ms in 10ms increments

(e.g. 1 = 10ms, 2 = 20ms).

6) Response time

[Formula for data sending time]

Communication specification

In addition to the bits in the above table, 1 bit is required for the start bit.
Minimum total number of bits ... 9 bits
Maximum total number of bits ... 12 bits

REMARKS

When communication parameter n7 "waiting time setting"

≠ "- - -", create the communication

request data without "waiting time" in the data format. (The number of characters is
decremented by 1.)

1

×

Number of data characters

(Refer to page 140)

×

Communication specification

(Total number of bits)

(See below)

= Data sending time (s)

Communication speed

(bps)

Name

Number of Bits

Stop bit length

1 bit

2 bits

Data length

7 bits

8 bits

Parity check

Yes

1 bit

No

0 bit

Computer

Inverter

Inverter

Computer

Inverter data processing time
= waiting time + data check time

(setting 10ms)

(12ms)

Computer

Inverter
Inverter

Computer


(refer to the following formula)

Inverter data processing time = waiting time + data check time

(set value 10ms)

(12ms)

10ms or
more required

10ms or
more required

(refer to the following formula)

STX

ACK

ENQ

Computer

Inverter
Inverter

Computer


(refer to the following formula)

Inverter data processing time = waiting time + data check time

(set value 10ms)

(12ms)

10ms or
more required

Data sending time

(refer to the following formula)

ENQ

Data sending time

Data sending time

Data sending time