8 additional function parameters, 1 remote setting function selection (pr. 59 ), Additional function parameters – MITSUBISHI ELECTRIC FR-S520E User Manual
Page 109
99
Additional function parameters
2
F
UNCT
IO
NS
2.8 Additional function parameters
2.8.1
Remote setting function selection (Pr. 59
)
* External running frequency (other than multi-speed) or PU running frequency
If the operation panel is located away from the control box, you can use contact
signals to perform continuous variable-speed operation, without using analog
signals.
Parameter
Name
Factory
Setting
Setting
Range
Remarks
59
Remote setting
function selection
0
0, 1, 2
Setting is enabled when Pr. 30 = "1"
REMARKS
•By merely setting this parameter, you can use the acceleration, deceleration and setting clear
functions of the motorized speed setter (FR-FK).
•When the remote function is used, the output frequency of the inverter can be compensated
for as follows:
External operation mode
Frequency set by RH/RM operation plus external analog
frequency command
PU operation mode
Frequency set by RH/RM operation plus setting dial or PU
digital preset frequency
* When you have set "1" in Pr. 53 "frequency setting operation selection", you need not
press the
.
Deceleration(RM)
Clear(RL)
Acceleration(RH)
Forward rotation
(STF)
Ou
tput
fr
e
q
uen
cy (H
z)
ON
ON
Power supply
ON
*
ON
ON
ON
ON
ON
When Pr. 59="2"
When Pr. 59="1"
ON
ON
ON
Monitor, frequency
setting mode
MODE
Press the to
complete setting.*
SET
Turn the setting dial to
make correction.
SET