99

Additional function parameters

2

F

UNCT

IO

NS

2.8 Additional function parameters

2.8.1

Remote setting function selection (Pr. 59

)

* External running frequency (other than multi-speed) or PU running frequency

If the operation panel is located away from the control box, you can use contact
signals to perform continuous variable-speed operation, without using analog
signals.

Parameter

Name

Factory

Setting

Setting

Range

Remarks

59

Remote setting
function selection

0

0, 1, 2

Setting is enabled when Pr. 30 = "1"

REMARKS

•By merely setting this parameter, you can use the acceleration, deceleration and setting clear

functions of the motorized speed setter (FR-FK).

•When the remote function is used, the output frequency of the inverter can be compensated

for as follows:
External operation mode

Frequency set by RH/RM operation plus external analog

frequency command

PU operation mode

Frequency set by RH/RM operation plus setting dial or PU
digital preset frequency

* When you have set "1" in Pr. 53 "frequency setting operation selection", you need not

press the

.

Deceleration(RM)
Clear(RL)

Acceleration(RH)

Forward rotation
(STF)

Ou

tput

fr

e

q

uen

cy (H

z)

ON

ON

Power supply

ON

*

ON

ON

ON

ON

ON

When Pr. 59="2"

When Pr. 59="1"

ON

ON

ON

Monitor, frequency

setting mode

MODE

Press the to

complete setting.*

SET

Turn the setting dial to

make correction.

SET