beautypg.com

MITSUBISHI ELECTRIC FR-S520E User Manual

Page 189

background image

179

Specification list

4

SPECI

F

ICATI

O

N

S

*1. When undervoltage or instantaneous power failure occurs, no alarm output is provided but

the output is shut off. After power restoration, the inverter may be run as it is. Depending on
the running status (e.g. load magnitude), however, overcurrent, regenerative overvoltage or
other protection may be activated at power restoration. (in the external operation mode)

*2. The braking torque indicated is a short-duration average torque (which varies with motor

loss) when the motor alone is decelerated from 60Hz in the shortest time and is not a
continuous regenerative torque. When the motor is decelerated from the frequency higher
than the base frequency, the average deceleration torque will reduce. Since the inverter
does not contain a brake resistor, use an optional brake resistor when regenerative energy
is large. (Available for the FR-S520E-0.4K to 3.7K only.) A brake unit (BU) may also be
used.

*3. Compatible with only the product having the built-in cooling fan.
*4. Available for the FR-S520E-0.4K to 3.7K only.
*5. Activated only when "1" is set in Pr. 40 "start-time earth (ground) fault detection selection".
*6. Activated only when external thermal relay input (OH) is selected in any of Pr. 60 to Pr. 63

(input terminal function selection).

*7. Temperature applicable for a short period such as transportation.

Co

n

tr

o

l s

p

e

c

if

ic

a

tio

n

s

Operational
functions

Maximum and minimum frequency settings, frequency jump
operation, external thermal relay input selection, automatic
restart after instantaneous power failure, forward/reverse
rotation prevention, slip compensation, operation mode
selection, PID control, computer link operation (RS-485).

Ou

tp

u

t s

ig

n

a

ls

Operating Status

1 open collector signal can be selected from
among inverter running, up-to-frequency,
frequency detection, overload warning, zero
current detection, output current detection, PID
upper limit, PID lower limit, PID forward/reverse
rotation, operation ready, current average value
monitor signal, maintenance timer alarm, minor
failure and alarm. 1 contact output (1 contact, 230V
0.3AAC, 30V 0.3ADC) signal can be selected.

Use
Pr. 64 and
Pr. 65 for
selection

For meter

1 signal can be selected from between output frequency and
motor current. Pulse train output (1440 pulses/s, 1mA full
scale)

Protective/warning function

Overcurrent shut-off (during acceleration, deceleration,
constant speed), regenerative overvoltage shut-off (during
acceleration, deceleration, constant speed), overload shut-
off (electronic thermal relay function), heatsink overheat, fan
failure (*3), stall prevention, brake transistor alarm (*4),
start-time output side earth (ground) fault protection (*5),
external thermal relay (*6), disconnected PU, retry count
over, communication error, CPU error, undervoltage (*1)

Env

ir

o

nm

en

t

Ambient
temperature

-10

°C to +50°C (non-freezing)

(-10

°C to +40°C for totally enclosed structure feature)

Ambient humidity

90%RH or less (non-condensing)

Storage
temperature (*7)

-20

°C to +65°C

Atmosphere

Indoors
(without corrosive gas, flammable gas, oil mist, dust and dirt etc.)

Altitude, vibration

Maximum 1000m above seal level, 5.9m/s

2

or

less(conforms to JIS C 60068-2-6)

This manual is related to the following products: