MITSUBISHI ELECTRIC FR-S520E User Manual
Page 66
56
Function (Parameter) list
P
a
ra
me
te
r L
ist
D
is
pl
a
y
f
u
nc
ti
on
s
52
Operation
panel display
data selection
0: Output frequency,
1: Output current,
100:Set frequency
during stop/output
frequency during
operation
1
0
53
Frequency
setting
operation
selection
0: Setting dial
frequency setting
mode
1: Setting dial
potentiometer mode
1
0
54
FM terminal
function
selection
0: Output frequency
monitor
1: Output current
monitor
1
0
55
Frequency
monitoring
reference
0 to 120Hz
0.1Hz
60Hz
56
Current
monitoring
reference
0 to 50A
0.1A
Rated
output
current
Aut
o
m
a
ti
c r
e
st
a
rt
func
ti
o
n
s
57
Restart
coasting time
0 to 5s, - - -
0.1s
- - -
58
Restart
cushion time
0 to 60s
0.1s
1s
Add
it
ion
al
f
u
nct
ion
59
Remote
setting
function
selection
0: Without remote
setting function
1: With remote setting
function
With frequency setting
storage function
2: With remote setting
function
Without frequency
setting storage
function
1
0
Func-
tion
Para-
meter
Indica-
tion
Name
Setting Range
Minimum
Setting
Increments
Factory
Setting
Refer
To:
Cus-
tomer
Setting