Additional function parameters

•Use Pr. 59 to select whether the remote setting function is used or not and whether

the frequency setting storage function* in the remote setting mode is used or not.
When "remote setting function - yes" is selected, the functions of signals RH, RM and
RL are changed to acceleration (RH), deceleration (RM) and clear (RL), respectively.
Use Pr. 60 to Pr. 63 (input terminal function selection) to set the signals RH, RM, RL.

* Frequency setting storage function

This function stores the remotely-set frequency (frequency set by RH/RM
operation) into memory.
When power is switched off once, then on, operation is resumed with that output
frequency value. (Pr. 59="1")

Pr. 59 Setting

Operation

Remote setting function

Frequency setting storage

function (E

2

PROM)

0

No



1

Yes

Yes

2

Yes

No