beautypg.com

17 speed display (pr. 37 ), Caution – MITSUBISHI ELECTRIC FR-S520E User Manual

Page 95

background image

85

Explanation of functions (parameters)

2

F

UNCT

IO

NS

2.3.17 Speed display (Pr. 37

)

• To display the machine speed, set in Pr. 37 the machine speed for 60Hz operation.

You can change the output frequency indication or set frequency of the
operation panel and parameter unit (FR-PU04) to the motor speed or machine
speed.

Parameter

Name

Factory

Setting

Setting

Range

Remarks

37

Speed display

0

0, 0.1 to 999

0:Output

frequency

Setting is enabled
when Pr. 30 = "1".

CAUTION

The motor speed is converted from the output frequency and does not match

the actual speed.

When you want to change the monitor (PU main display) of the operation

panel, refer to Pr. 52 "operation panel display data selection" and
communication parameter n16 "PU main display screen data selection".

Since the operation panel indication is 3 digits, make a setting so that the

monitor value does not exceed "999". If the Pr. 1 value is higher than 60Hz and
Pr. 1 value × Pr. 37 value > 60Hz × 999

(write error) occurs when Pr. 1 or Pr. 37 is written.

REMARKS

When the speed is set in Pr. 37 (Pr. 37

0), the speed is monitored and displayed in the

monitor/frequency setting mode.
At this time, setting can be made in the minimum setting (display) increments of 0.01r/min.
Due to the limitations on the resolution of the set frequency, the indication in the second
decimal place may differ from the setting.

CAUTION

Make sure that the running speed setting is correct.
Otherwise, the motor might run at extremely high speed, damaging the
machine.

Related parameters

To choose running speed monitor display

Pr. 52 "operation panel display data selection"

(refer to page 94)

FR-PU04 display switching

Communication parameter n16 "PU main display screen data

selection" (refer to page 157)

This manual is related to the following products: