MITSUBISHI ELECTRIC FR-S520E User Manual

Page 39

background image

29

Input terminals

1

WI

RING

*1: Also stopped by the

. Refer to page 109.

(2) Three-wire type connection (STF, STR, STOP)

A three-wire type connection is shown on
the right. Assign the start self-holding
signal (STOP) to any of the input terminals.
To make a reverse rotation start, set Pr. 63
to "- - -" (factory setting).
1) Short the signals STOP-SD to enable

the start self-holding function. In this
case, the forward/reverse rotation signal
functions only as a start signal.
(Note) Assign the stop signal to any of

Pr. 60 to Pr. 62 (input terminal
function selection).

2) If the start signal terminals STF (STR)-

SD are shorted once, then opened, the
start signal is kept on and starts the
inverter. To change the rotation direction,
short the start signals STR (STF)-SD
once, then open it.

3) The inverter is decelerated to a stop by

opening the signals STOP-SD once. For
the frequency setting signal and the
operation of DC injection brake at a stop
time, refer to paragraphs 2) to 4) in (1)
Two-wire type connection. The right
diagram shows 3-wire type connection.

4) When the signals JOG-SD are shorted, the STOP signal is invalid and the JOG

signal has precedence.

5) If the output stop signals MRS-SD are shorted, the self-holding function is not

deactivated.

DC Injection Brake and Coasting to Stop Functionality

Operation

Mode

DC Injection
Brake

External Operation or Combined

Operation

Pr. 79 = "0", "2", "3"

PU Operation or Combined

Operation

Pr. 79 = "0", "1", "4"

Terminals STF

(STR)-SD

disconnected

(*1)

Set frequency

changed to 0Hz

Stop key

Set frequency

changed to 0Hz

DC injection
brake enabled

DC injection brake
operated at not
more than "DC
injection brake
operation
frequency" set in
Pr. 10

DC injection brake
operated at 0.5Hz
or less.

DC injection brake
operated at not
more than "DC
injection brake
operation
frequency" set in
Pr. 10

DC injection brake
operated at 0.5Hz
or less.

DC injection
brake disabled

Coasted to a stop
at not more than
"DC injection
brake operation
frequency" set in
Pr. 10

Coasted to a stop
at 0.5Hz or less.

Coasted to a stop
at not more than
"DC injection
brake operation
frequency" set in
Pr. 10

Coasted to a stop
at 0.5Hz or less.

Reverse

rotation start

NFB

Time

STF

STR (Pr.63= "- - -" )

STOP

Start

Stop

ON

ON

Power
supply

Inverter

Out

put

f

requ

enc

y

Stop

Forward
rotation start

3-wire type connection example

SD

R, S, T

STOP