3 link startup mode selection (n10 ), Ge 153) – MITSUBISHI ELECTRIC FR-S520E User Manual

Page 163

background image

153

2

F

UNCT

IO

NS

Communication parameters

[Explanation of table]

External

: Operation is valid only from external terminal signal.

Computer

: Operation is valid only from computer.

Combined

: Operation is valid from either of external terminal and computer.

: Operation is invalid from either of external terminal and computer.

2.16.3 Link startup mode selection (n10

)

The parameter number in parentheses is the one for use with the parameter unit (FR-
PU04).

RH, RM,

RL, REX

selection

function

Remote setting
(RH, RM, RL)

Computer

External

Computer

External

Pr. 59 =
"1", "2"

15-speed selection (REX)

MRS

selection

function

PU operation interlock
(MRS)

External

External

External

External Pr. 79 = "7"

CAUTION

When Pr. 79 "operation mode selection" is set to "7" (PU operation interlock

function), only the external terminal is made valid independently of the n8 and

n9 settings because the MRS terminal is shared.

The operation mode at power on and at power restoration after instantaneous

power failure can be selected.

Set "1" in n10 to select the computer link operation mode.

After a link start, parameter write is enabled with a program.

Parameter

Name

Factory

Setting

Setting

Range

Remarks

n10 (340)

Link startup
mode selection

0

0, 1

Setting is enabled when Pr. 30 = "1"

Operation

location

selection

n8 (Pr. 338) "operation
command source"

0:

Computer

0:

Computer

1:

External

1:

External

Remarks

n9 (Pr. 339) "speed
command source"

0:

Computer

1:

External

0:

Computer

1:

External