beautypg.com

Bias control, Figure 62 – Grass Valley Kayenne v.3.0 User Manual

Page 82

background image

82

KAYENNE — User Manual

Section 2 — Concepts

Figure 62. Continuity Control Setting -1.0

Bias Control

The

BIAS

control determines whether the path will be pulled towards the

previous or the following keyframe. With extreme settings, all of the
biasing will occur either before or after KF2. With bias set to 0 (zero), the
curve through the keyframe is gentle as shown in

Figure 63

.

Note

A Tension vector must be present for Bias control to be available.

Figure 63. Bias Control Setting Zero

With the bias set to 1.0, the path is pulled towards the following keyframe.
Entry into and exit from the keyframe is a straight line from the previous

Continuity = -1.0

KF1

KF2

KF3

0721_06_52_r0

+

Continuity

Vector

Bias = 0.0

KF1

KF2

KF3

Bias

Vector

Tension

Vector

+

-

0721_06_53_r0