Source Patching

quickly swap out a defective device during a show without having to
reconfigure the engineering sources. In this case logical names seen by the
production personnel would be identical for that content, even though the
actual device playing the material changed.

Note

Source Patching is the bridge between engineering sources and logical
sources. Both TD and EIC should make reference to this menu when
resolving source issues. The mechanism is similar in concept to a physical
patch panel. Effects and all source selections are based on logical sources.
Tally and associations with external devices are based on engineering
sources.

Logical Sources

The Source Patch menu scrolling list has more Logical IDs than physical
inputs (97-200 on 4-ME Kayenne systems). These can be used to permit
alternative processing of the same incoming signal. For example, a camera
input can be assigned to two Logical IDs, and one of these logical sources
could be given sepia-tone color correction using Source Rules for a special
effect. Selecting these different versions of that same source would auto-
matically apply or clear the sepia-tone effect, as needed.

Using Source Patching for Effects Portability

Source patching makes it possible to build effects on a Kayenne system in
one facility or truck, and then use those effects on a different Kayenne
system at another facility that has different Engineering source configura-
tions. Building a Source Patch table prior to effects creation simplifies the
migration of effects between facilities.

Plan out the sources you will use for a show, even ones that may not exist
on the system where you are creating the effects. Build a list of Logical
sources in the Source Patch menu without regard to the currently associ-
ated Engineering sources. After the list is built, map one of the facility’s
existing Engineering sources to each Logical source. If physical devices
don't exist for some planned sources, substitute a dummy Engineering
source. You can then build your effects and verify that they run properly.
When you are satisfied with the effects, save the Suite Prefs and E-MEM
effects you created to USB Memory Stick. At the new facility, load these
files into that Kayenne system. Do not load the Eng Setups of one facility
into the other, as this will overwrite that facility’s existing Engineering con-
figuration.

Once the Suite Prefs and effects are loaded at the new facility, go to the
Source Patch menu and map the appropriate Engineering sources of the
new facility to the original list of Logical sources. Your effects should now
run as previously designed without having to edit or rebuild them. When
satisfied the effects run correctly at the new facility, save that Suite Prefs
under a different name for use the next time you use this facility. Do not