Configuring the nms – H3C Technologies H3C S3100 Series Switches User Manual
Page 683

1-8
[Sysname] snmp-agent sys-info version all
[Sysname] snmp-agent community read public
[Sysname] snmp-agent community write private
# Set the access right of the NMS to the MIB of the SNMP agent.
[Sysname] snmp-agent mib-view include internet 1.3.6.1
# For SNMPv3, set:
z
SNMPv3 group and user
z
security to the level of needing authentication and encryption
z
authentication protocol to HMAC-MD5
z
authentication password to passmd5
z
encryption protocol to DES
z
encryption password to cfb128cfb128
[Sysname] snmp-agent group v3 managev3group privacy write-view internet
[Sysname] snmp-agent usm-user v3 managev3user managev3group authentication-mode md5 passmd5
privacy-mode des56 cfb128cfb128
# Set the VLAN-interface 2 as the interface used by NMS. Add port Ethernet 1/0/2, which is to be used
for network management, to VLAN 2. Set the IP address of VLAN-interface 2 as 10.10.10.2.
[Sysname] vlan 2
[Sysname-vlan2] port Ethernet 1/0/2
[Sysname-vlan2] quit
[Sysname] interface Vlan-interface 2
[Sysname-Vlan-interface2] ip address 10.10.10.2 255.255.255.0
[Sysname-Vlan-interface2] quit
# Enable the SNMP agent to send Trap messages to the NMS whose IP address is 10.10.10.1. The
SNMP community name to be used is “public”.
[Sysname] snmp-agent trap enable standard authentication
[Sysname] snmp-agent trap enable standard coldstart
[Sysname] snmp-agent trap enable standard linkup
[Sysname] snmp-agent trap enable standard linkdown
[Sysname] snmp-agent target-host trap address udp-domain 10.10.10.1 udp-port 5000 params
securityname public
Configuring the NMS
The S3100 series Ethernet switches support H3C’s QuidView NMS. SNMPv3 adopts user name and
password authentication. When you use H3C’s QuidView NMS, you need to set user names and
choose the security level in [Quidview Authentication Parameter]. For each security level, you need to
set authorization mode, authorization password, encryption mode, encryption password, and so on. In
addition, you need to set timeout time and maximum retry times.
You can query and configure an Ethernet switch through the NMS. For more information, refer to the
corresponding manuals of H3C’s NMS products.