Link monitoring – H3C Technologies H3C S3100 Series Switches User Manual

Page 1029

background image

1-4

z

OAM connections can be initiated only by OAM entities operating in active OAM mode, while those

operating in passive mode wait and respond to the connection requests sent by their peers.

z

No OAM connection can be established between OAM entities operating in passive OAM mode.

After an Ethernet OAM connection is established, the Ethernet OAM entities on both sides exchange

Information OAMPDUs periodically to keep the Ethernet OAM connection valid. If an Ethernet OAM

entity receives no Information OAMPDU for five seconds, the Ethernet OAM connection is

disconnected.

The interval to send Information OAMPDUs is determined by a timer. Up to ten Information OAMPDUs

can be sent in a second.

Link monitoring

Error detection in an Ethernet is difficult, especially when the physical connection in the network is not

disconnected but network performance is degrading gradually. Link monitoring is used to detect and

indicate link faults in various environments. Ethernet OAM implements link monitoring through the

exchange of Event Notification OAMPDUs. Upon detecting a link error event listed in

Table 1-4

, the

local OAM entity sends an Event Notification OAMPDU to notify the remote OAM entity. With the log

information, network administrators can keep track of network status in time.

Table 1-4

describes the

link events.

Table 1-4 Ethernet OAM link error events

Ethernet OAM link events

Description

Errored symbol event

An errored symbol event occurs when the number of
detected symbol errors over a specific detection
interval exceeds the predefined threshold.

Errored frame event

An errored frame event occurs when the number of
detected error frames over a specific interval exceeds
the predefined threshold.

Errored frame period event

An errored frame period event occurs if the number of
frame errors in specific number of received frames
exceeds the predefined threshold.

Errored frame seconds event

When the number of error frame seconds detected on
a port over a detection interval reaches the error
threshold, an errored frame seconds event occurs.