2 logging in through the console port, Introduction, Logging in through the console port – H3C Technologies H3C S3100 Series Switches User Manual
Page 33

2-1
2
Logging in through the Console Port
Introduction
To log in through the Console port is the most common way to log into a switch. It is also the prerequisite
to configure other login methods. By default, you can locally log into an S3100 Ethernet switch through
its Console port only.
lists the default settings of a Console port.
Table 2-1 The default settings of a Console port
Setting
Default
Baud rate
9,600 bps
Flow control
None
Check mode (Parity)
None
Stop bits
1
Data bits
8
To log into a switch through the Console port, make sure the settings of both the Console port and the
user terminal are the same.
After logging into a switch, you can perform configuration for AUX users. Refer to section “
” for more.
Logging in through the Console Port
Following are the procedures to connect to a switch through the Console port.
1) Connect the serial port of your PC/terminal to the Console port of the switch, as shown in
.
Figure 2-1 Diagram for connecting to the Console port of a switch