[SwitchB-ospf-1-area-0.0.0.0] network 10.1.0.0 0.0.0.255

[SwitchB-ospf-1-area-0.0.0.0] quit

[SwitchB-ospf-1] quit

[SwitchB] interface vlan-interface 10

[SwitchB-Vlan-interface10] ospf bfd enable

[SwitchB-Vlan-interface10] quit

Configure BFD parameters.

# Configure Switch A.

[SwitchA] bfd session init-mode active

[SwitchA] interface vlan-interface 10

[SwitchA-Vlan-interface10] bfd min-transmit-interval 500

[SwitchA-Vlan-interface10] bfd min-receive-interval 500

[SwitchA-Vlan-interface10] bfd detect-multiplier 7

[SwitchA-Vlan-interface10] bfd authentication-mode simple 1 zhang

[SwitchA-Vlan-interface10] quit

[SwitchA] quit

# Configure Switch B.

[SwitchB] bfd session init-mode active

[SwitchB] interface vlan-interface 10

[SwitchB-Vlan-interface10] bfd min-transmit-interval 500

[SwitchB-Vlan-interface10] bfd min-receive-interval 500

[SwitchB-Vlan-interface10] bfd detect-multiplier 6

[SwitchB-Vlan-interface10] bfd authentication-mode simple 1 zhang

Verify the configuration.

# Display the BFD information of Switch A.

display bfd session

Total Session Num: 1 Init Mode: Active

Session Working Under Ctrl Mode:

LD/RD SourceAddr DestAddr State Holdtime Interface

3/1 10.1.0.102 10.1.0.100 Up 1700ms vlan10

# Display the OSPF neighbor information of Switch A.

display ospf peer

OSPF Process 1 with Router ID 192.168.1.40

Neighbor Brief Information

Area: 0.0.0.1

Router ID Address Pri Dead-Time Interface State

10.1.0.102 10.1.0.100 1 31 vlan10 Full/DR

# Enable BFD debugging on Switch A.

debugging bfd scm

debugging bfd event

debugging ospf event

terminal debugging

# When the link between Switch B and the Layer 2 switch fails, you can see that Switch A can quickly

detect the changes on Switch B.

%Nov 12 18:34:48:823 2005 SwitchA BFD/5/LOG: Sess[10.1.0.102/10.1.0.100, vlan10], Sta :

UP->DOWN, Diag: 1

%Nov 12 18:34:48:824 2005 SwitchA RM/4/RMLOG:OSPF-NBRCHANGE: Process 1, Neighbour 10.1.0.102

(vlan10) from Full to Down

*0.50673825 SwitchA BFD/8/SCM:Sess[10.1.0.102/10.1.0.100, vlan10],Oper: Reset