Configuring Access Manager
4-10
Access Manager 2000 User Manual
Digiboard COM port. Refer to the DOS manual for proper use of the
MODE command. Do not duplicate filenames listed in Table 2-1,
“Access Manager Installation Files,” on page 2-4.
To output alarm messages to another computer:
1. In the
Alarm Printer Filename
field, enter the comline
name.
2. Leave the
Printer Type
field blank. It is not applicable.
Alarm Channel Protocol
The
Alarm Channel Protocol
data entry field appears in the
Editing the Alarm Destination screen. The
Alarm Channel
Protocol
option is selected by moving the cursor to that line and
pressing
to bring up the selection
Alarm Channel
Protocol
screen.
If you are using a serial or parallel printe , select the
PLAIN ENGLISH
MESSAGE
option. This sends the entire alarm information in ASCII
format. The alarms are printed one alarm message per line.
If you are outputting to a serial port or disk file, select the
TERSE
MESSAGE
option. This sends information in the following formats:
■
the date, time, and node name alarm output in an ASCII format, and
■
the alarm status in an ASCII-formatted hexadecimal format.
Do not use this option with a serial or parallel printer.