Verilink Access Manager 2000 (896-502037-001) Product Manual User Manual
Page 171

Configuring circuit elements
Access Manager 2000 User Manual
5
-47
Far-End Circuit Elements
Access Manager supports configuration of CSU circuit elements, whether
far-end or near-end. Far-end CSU circuit elements are accessed through
the ESF Data Link. For this capability to function, follow these steps:
1. The parent node of the near-end circuit element must be installed
and operational.
2. A direct or dial-up connection to the host PC must be in place for
the near-end node. (DIU circuit elements can be configured if, and
only if, the parent node is near-end.)
3. The near-end circuit element must be installed and operational.
4. The parent node of the (far-end) circuit element must be installed
and operational.
5. The far-end circuit element must be defined in the database.
6. A circuit must be defined between a near-end circuit element and
the far-end circuit element to be configured.
7. The far-end circuit element may now actually be accessed.
The Configuration: AS2000 Plug screen has the same selections as the
Configuration: ConnecT1 Plus Plug screen.
To select the range of circuit elements:
1. Starting from the Main Menu, select
Configuration
. The
Configuration Menu appears.
Select the circuit
element range