Configuration Options for AS2000 and ConnecT1 Plus

Access Manager 2000 User Manual

5

-97

timing and probably requires some trial and error. First, choose

ST

and

check the end-to-end data transmission on the data port. If transmission
does not work properly, choose

INVERT S

.

EQP Handshaking

The DIU 2130 and DIU 1130 supports five handshaking signals on each
data port. The V.35 names appear in the DIU menu screen, although
RS449 and RS530 interfaces are also available. Set each signal to

N

or

Y

.

The DIU 2130 and data port handshaking signals are listed below.

Table 5-12

DIU 2130 and Data Port Handshaking Signals

Loss of Signal

Select from one of the following options:

NO

Do not generate a Loss of Signal signal.

RTS

Generate an LOS alarm when RTS is missing.

DTR

Generate an LOS alarm when DTR is missing.

Handshaking Signals

Circuit

Direction

EQP Handshaking Options

V.35

(screen)

RS449

RS530

N (default)

Y

RTS

RS

CA

to DIU

signal from data equipment

forced on (asserted)

DTR

TR

CD

to DIU

signal from data equipment

forced on (asserted)

CTS

CS

CB

from DIU

follow conditioned RTS from

data equip.

(Note 1

forced on (asserted)

DSR

DM

CC

from DIU

follow conditioned DTR from

data equip. (Note 2)

forced on (asserted)

RLSD

(DCD)

RR

CF

from DIU

on

(Note 3)

forced on (asserted)

NOTE 1. (CTS) Set this option to

NO

(default) if you want CTS from the DIU to follow conditioned RTS from the data

equipment. If

NO

, CTS turns off automatically if the associated NCC, CCC, or TAC goes into an LOF state or receives a

Yellow (i.e., RAI) alarm regardless of RTS. Or, set this option to

YES

to permanently turn on DSR.

NOTE 2. (DSR) Set this option to

NO

(default) if you want DSR from the DIU to follow conditioned DTR from the data

equipment. If

NO

, DSR turns off automatically if the associated NCC, CCC, or TAC goes into an LOF state or receives

a Yellow alarm regardless of DTR. Or, set this option to

YES

to permanently turn DSR on.

NOTE 3. (RLSD) Set this option to

NO

(default) if you want RLSD on except when the associated NCC, CCC, or TAC

goes into an LOF state. Or, set the RLSD t

YES

to permanently turn it on.