Displaying individual circuit element status
Access Manager 2000 User Manual
8-21
Reviewing DIU statu
This section covers status and revision levels for the DIU 2130, DIU
2140, and DIU 1130. All associated screens show the circuit element
number [shelf, slot] and type, DIU name, associated DS1 circuit name,
and current DIU hardware and firmware revisions. Additional status
information also appears for each EQPT data channel (i.e., data port) of
the current DIU.
ES-L, ES, UAS,
BER Sec Exceeded
No
The number of user-defined ES-L, ES, UAS,
and/or BER alarm threshold seconds with
excessive error counts have not been
exceeded and therefoer have not caused an
alarm. These thresholds are displayed for the
incoming signals from both the EQPT and
network (NET).
For more information on these alarm
threshold setting options, see AT&T
Reference 54016.
Test Signal
Circuit element is sending a test signal.
Yellow Alarm
See ANSI T1.403
Field
Value
Meaning
Near-End Looped
No
A loopback is not in progress on an EQPT
channel (that is, data port) of the near-end
DIU.
Far-End Looped
No
A loopback is not in progress on an EQPT
channel (that is, data port) of the far-end
DIU.
Sending Loop Up
No
A loop-up code is not being sent to the far-
end DIU to activate a channel (that is, data
port) loopback there.
Sending Loop Down
No
A loop-up code is not being sent to the far-
end DIU to deactivate a channel (that is,
data port) loopback there.
Sending Test
Pattern
No
The DIU is not currently applying a test
signal to an EQPT channel (that is, data
port).
Runnign BER Test
No
A bit error rate test is not currently in
progress on the DIU.
Field
Value
Meaning