Csu acceptance testing – Verilink Access Manager 2000 (896-502037-001) Product Manual User Manual
Page 232

Configuring the T1 Network
5-108
Access Manager 2000 User Manual
CSU acceptance testing
Before performing the CSU acceptance tests from an Access Manager
2000 PC, verify the following:
The Access Manager 2000 PC is powered up, started, and ready for
operation.
The Access System 2000 node definitions are already entered in the
Access Manager 2000 database.
The CSU of each NCC or TAC to be tested is configured.
If the Access Manager 2000 PC interfaces with the Access System
2000 over a modem or multiplexer, the node to be tested has already
been auto-configured for modem or multiplexer communication.
To perform the CSU acceptance tests from an Access Manager 2000 PC,
proceed with the following steps.
Note:
These tests use the CSU repeater loopback (RLB) function. The
RLB remains active until the operator-defined time-out period
ends. For test purposes, you can temporarily change this interval
from an Access Manager 2000 PC. The default RLB time-out
setting is one minute.
1. Start up the Access Manager 2000 PC and log in by entering the
proper user name and password. A user level of 4 is required for
these tests. Also verify that the current Access Manager 2000
software revision is 2.3B or higher. This revision appears at the
bottom of the Main Menu.
2. Access the CSU to be tested and temporarily set the repeater
loopback (RLB) time-out option of each CSU to be tested to
1 HR
.
3. Starting from the Main Menu of Access Manager 2000, select
On-
line Access
. The On-line Access (Select Node) Menu appears.
4. Select the Access System 2000 node in which the desired NCC or
TAC is located and press
. The On-line: AS2000 screen
appears.
Enter