Configuration Options for 551VST Elements
Access Manager 2000 User Manual
5
-63
■
These registers are known as near-end and far-end user registers
because only the user can reset them. The Telco can examine this
data but cannot reset these registers.
■
The default setting for this option is
YES
.
This option permits Access Manager to retrieve and store the
performance data from a far-end CSU through this CSU.
For this option to work, the following two conditions must be met:
a. The
Retrieve Performance Data
option must also be
set to
YES
.
b. An Access Manager circuit must be configured between the
near-end and far-end CSUs.
The following descriptions will aid you in setting the
Retrieve Far-
End Performance Data
field:
■
If access to a far-end CSU is not required, set this option to
NO
.
■
If access to a far-end CSU is required for collection of performance
data, set this option to
YES
.
The default setting for this option is
NO
.
Before you can enable alarm reporting with this option, the parent node
must have the following:
a. Its
Enable Alarm Reporting
option enabled, and
b. A downloaded alarm path
If a CSU circuit element should not report alarm conditions, set this
option to
NO
.
If a CSU circuit element is accessed only through the ESF Data Link, set
this option to
NO
.
To enable alarm reporting for CSU circuit elements accessed only
through the Data Link, set this option to
YES
for the near-end CSUs
whose parent node is accessed directly, by modem, or by statistical
multiplexer.
The default setting for this option is
YES
.
Retrieve Far-En
Performance Data
Enable Alarm
Reporting