Gh tableb-3, Modem, Configuration – Verilink Access Manager 2000 (896-502037-001) Product Manual User Manual
Page 358

B-6
Access Manager 2000 User Manual
Table B-3 Modem Configuration for TABS Protocol
Parameter
Smartmodem
1200
Switch Position
Option
Smartmodem 2400 AT
Command
DTR status ignored
SW1 down
Ignores DTR
&D0&W
Result code format
SW2 down
Number
V0&W
Result code display
SW3 up
Codes are not displayed
Q1&W
Character echo
SW4 down
Characters not echoed in
command state
E0&W
Auto-answer
SW5 up
Enabled
S0=1&W
Carrier detect
SW6 up
Reflects actual result of
attempt to connect
&C1&S1&W
TELCO jack type (Note 2
SW7 up
RJ-11, RJ-41S,
RJ-45S
&J0&W
SW7 down
RJ-12, RJ-13
&J1&W
Command
recognition
SW8 up
Disabled
Internal jumper set to
disable command
recognition
(Note 3)
Communication standard
at 1200 bps
SW9 up
Bell 212A
B1&W
Response to DTR
transition
(when SW1 is up)
SW10 up
Hangs up and goes to
command state
Set by SW1 option
NOTE 1. Factory position indicated by boldface.
NOTE 2. Position of SW7 depends on the type of phone jack used. Most installations use an RJ-11 jack (SW7 up).
NOTE 3. The internal jumper should be set to enable command recognition to configure the other options in the table.
After the configuration is complete, power down the modem and set the internal jumper to disable command
recognition.