Verilink Access Manager 2000 (896-502037-001) Product Manual User Manual
Page 217

Configuration Options for AS2000 and ConnecT1 Plus
Access Manager 2000 User Manual
5
-93
Installed and Operational
This setting should be the same as the
Installed and
Operational
option setting of the associated CSU.
Enable Alarm Reporting
This setting should be the same as the
Enable Alarm Reporting
option setting of the associated CSU.
Save Configuration to DIU
To store the configuration from the database into the DIU, set the
Save
configuration to DIU
option to
Y
. If this option is set to
N
, any
updated changes are saved to the database but are not downloaded to the
DIU.
Connected CSU Shelf and Plug Numbers
Enter the Access System 2000 shelf number and plug-in slot number of
the CSU to which the DIU is connected. This setting allows the DIU to
send data to and receive data from that CSU over the DIU data bus
assigned to that module. The shelf number can be from 1 to 4.
Channel Assignment
Assign one or more DS0 channels of the DS1 line to each DIU 2130 and
DIU 1130 data port, based on the data equipment’s transmission speed
(
EQP Speed
). One channel is required for every 56 kbps or 64 kbps of
bandwidth.
For example, if the customer data equipment operates at 256 k b ps, it
needs four DS0 channels (4 channels x 64 kbps per channel = 256 kbps
bandwidth) for DS1 transmission.
There are three types of channels:
Contiguous
The channel assignments are in numerical sequence (for
example: Port 1 = 1-3, Port 2 = 14-17, and so on, for the
ports of other DIUs used with the same CSU). Contiguous
channel assignments allow the DIU 2130 and DIU 1130
to interface properly with AT&T Accunet bundled DS0
applications.