Verilink Access Manager 2000 (896-502037-001) Product Manual User Manual
Page 157

Configuring nodes
Access Manager 2000 User Manual
5
-33
Error messages
If you’ve made an error in selecting your alarm path parameters, one of the following
error message will appear on your screen.
Error Message
Cause
Corrective Action
Invalid USE on Primary
Path
You selected a
Use
type other
than
NONE
,
SEN
, or
BACKU
.
Go to the
Use
field and verify that each
alarm path has a value of eithe
NONE
,
SEN
, or
BACKU
.
Invalid USE on
Secondary Path
Invalid Device
specified on Primary
Path
You selected a
Device Type
other than
DIREC
,
MODEM
,
STAT-MUX
, or
X.25 PA
.
Go to the
Device Type
field and verify that
each alarm path has a value of eithe
DIREC
,
MODEM
,
STAT-MUX
, or
X.25 PA
.
Invalid Device
specified on Secondary
Path
At least one SEND path
must be specified
A
BACKUP
path has been
selected with no existing
SEND
path.
If you want to use a backup path, go to the
Use
field and see which alarm path you’ve
labeled
BACKU
. Change the other alarm
path’s
Use
field to
SEN
.
Primary and Auxiliary
device types must be
the same
Two different device types were
selected.
Go to the
Device Type
field and verify that
both alarm paths are either
MODEM
,
STAT-MUX
, or
X.25 PA
.
Time format must be 1-
59 SEC, 1-59 MIN, 1-24
HR
• The
Retry Interval
is not
in the proper format, or
• The
Wait Interval
is not in
the proper format.
Go to the
Retry Interval
and
Wait
Interval
fields. Verify the following:
• The time unit is abbreviated correctly.
• The number is appropriate to the time
unit. (For example, you haven’t entered
27 HRS
.)
BACKUP unreachable
because SEND set for
continuous
A
BACKUP
path is specified while
the
SEND
path set for continuous
(attempts = 0). In other words, if
the
SEND
path is set to 0, it never
gives up, and a
BACKUP
path is
irrelevant.
Either:
• Set the
SEND
path for 1 to 256 attempts,
or
• Change the alarm path
Use
field from
BACKUP
to
NONE
.
X.25 PAD supported only
by AS2000 equipment
User specified X.25 PAD for use
with non-AS2000 equipment
Check you
Alarm path
and
Query Path
setups to see which of the following
connections you’re using: direct, modem, or
stat mux. Then change the entry in the
Device Type
field to reflect that.