As2000 node – Verilink Access Manager 2000 (896-502037-001) Product Manual User Manual
Page 287

Displaying individual circuit element status
Access Manager 2000 User Manual
8-17
Note:
The single-line 551VST List 1/A and List 2 also have an Enable
Alarm Latch configuration, showing whether the local BER
alarm deactivates on clearing (NO) or stays on until manually
cleared (YES).
To view the current status for a AS2000 or ConnecT1 Plus circuit
element:
Move the cursor to
Status-Element
, and press
. A
Circuit
Status screen for the first circuit element appears. Each type of circuit
element has specific screen.
The circuit elements and their corresponding screens are as follows:
CRC/Frm Bit Errors
Yes, No The framing bit error are being received
from the EQPT, while no CRC errors are
being received from the NET.
For ESF framing,
YES
indicates that
CRC errors are being received.
For SF (D4) framing,
YES
indicates that
frame bit errors are being received.
BPV Errors
No
BPV error are not being received fro
either the EQPT side or NET side.
DTE (EQPT)/SPAN
(NET) Looped
No
Neither an RLB nor an ELB is in progress
(EQPT side), and either an LLB or PLB is
in progress (NET side).
ESF Framing toward
the NET
Yes
But since ESF toward the EQPT is NO, the
framing toward the EQPT is SF.
B8ZS Encode
No
Neither the network (NET) nor the
equipment (EQPT)is set for B8ZS line
coding (transmit direction).
B8ZS Decode
No
Neither the NET nor the EQPT is set for
B8ZS decoding (receive direction).
Regen Transmit CRC
YEL AL Tran Enable
No
YEL AL Transcode
To
No
Yellow alarms are not currently being
transcoded from the network to the
equipment, or from the equipment to the
network.
Field
Value
Meaning
AS2000 node
Enter