beautypg.com

Verilink Access Manager 2000 (896-502037-001) Product Manual User Manual

Page 260

background image

Analyzing Performance Data

7-10

Access Manager 2000 User Manual

If you chose

Route

in Step 8, the Select A Route screen

appears. Place the cursor at the route to be analyzed, and press

. All the circuit elements associated with the route are

listed.

9. The Select A Circuit Element screen appears after a period of time

dependent on the size of the record log.

If, instead of getting this menu, you get a message that there is no
detail data, you cannot analyze the performance data. There are
three possible reasons for this message:

The circuit elements associated with the selected node, location,
route or circuit have no data that meets the filter’s minimum
criterion. (That is, a circuit element is only listed for further analysis
if it has a percentage of availability and percentage of error-free
seconds less than or equal to the minimum of the filter.)

The circuit elements associated with the selected node, location,
route, or circuit are not configured.

No data was collected by Access Manager for one or more of the
following reasons:

Access Manager was not operating during the time period
selected.

Polling was disabled for the time period selected.

The

Installed and Operational

option in the

selected node and/or circuit elements are set to

NO

.

The

Retrieve Performance Data

option for the circuit

elements (associated with the selected node, location, route, or
circuit) are set to

NO

.

Enter