Verilink Access Manager 2000 (896-502037-001) Product Manual User Manual
Page 186

Configuring the T1 Network
5-62
Access Manager 2000 User Manual
This option determines whether the circuit element is installed and
operational. This option, marked with an asterisk (*), must be set to
YES
to enable any of the subsequent options (including collection of
performance monitoring data, alarm reporting, and so on).
Before Access Manager will allow you to set this option to
YES
for the
circuit element, you must set the
Installed and Operational
option for the circuit element’s parent node to
YES
.
The default setting is
NO
.
Performance data is stored in registers of CSU circuit elements. Each
CSU circuit element has registers to store data. Access Manager can
access these registers through the
Retrieve Performance Data
function. Use the following conditions for setting this field:
■
If the circuit element is accessed only through the ESF Data Link,
set this option to
NO
, regardless if performance data is to be
retrieved. A CSU accessed only by the ESF Data Link is a far-end
CSU, and it should have its data collected by the near-end CSU.
■
If the CSU circuit element is a near-end CSU, set this option to
YES
if retrieval of near-end or far-end performance data is desired.
Setting
Retrieve Performance Data
to
YES
is sufficient to
enable retrieval of near-end performance data, but not sufficient to
retrieve far-end performance data. For this, you’ll need to set the
Retrieve Far-End Performance Data
option.
Enable EQP SIde B8ZS Decode
Regenerate CRC to EQP
EQP Side ESF Framing
Enable YEL Transcode to EQP
Idle Code Flags
a. For a remote 4016 L1, you must set this option through the hardware.
KEY:
= available
= available in some revisions =
not available
standalone CSUs
551VST-type CSU configuration
option
List 1/A
List 1/B
List 2
4016-R
4016 L1 4016 L2
Installed and
Operational
Retrieve
Performance Data