Monitoring and Troubleshooting Access Manager

8-20

Access Manager 2000 User Manual

6. After viewing the current status, press

to return to the On-line

Access Menu.

Reviewing CSU status

Except for Low Densit , the CSU monitors the status conditions for both
the NET and EQPT (i.e, data equipment) sides. Loopbacks apply to one
side only. The status items are as follows:

Field

Value

Meaning

Loss of Signal

See AT&T Reference 62411.

Loss of Frame

See AT&T Reference 54016.

Out of Frame

Although this condition, as defined in AT&T
Reference 54016, might not last long enough
to be visible to the operator, the CSU keeps
the

YES

indication alive for up to 1 second

after the condition clears, to make it visible.

AIS (Alarm
Indication
Signal)

See ANSI T1.403.

CRC Error

See

Out of Frame above. The CRC-6 error

indication is also kept alive for 1 second.

Low Density

The circuit element is stuffing ONEs into the
signal it has been configured to do when
receiving a low density signal. This only
applies to the EQPT side.

Active ELB, LLB,
RLB, PLB

No

None of these loopbacks are in progress.
These loopbacks are activated and
deactivated by commands sent over the ESF
Data Link.

BPV Error

See

Out of Frame above. The BPV error

indication is also kept alive for 1 second.