Table B-2 Modem Configuration for OSI Protocol without DTR Lead

NOTE 1. Factory position indicated by boldface.

NOTE 2. Position of SW7 depends on the type of phone jack used.
Most installations use an RJ11 jack (SW7 up).

Parameter

Smartmodem

1200

Switch Position

Option

Smartmodem 2400 AT

Command

DTR status ignored

SW1 down

Ignores DTR state if

signal drops

&D0&W

Result code format

SW2 down

Numbers

V0&W

Result code display

SW3 down

Codes are displayed

Q0&W

Character echo

SW4 down

Characters not

echoed in command

state

E0&W

Auto-answer

SW5 down

Disabled

S0=0&W

Carrier detect and data set
read

SW6 up

Reflects actual result of

attempt to connect

&C1&S1&W

TELCO jack type
(Note 2)

SW7 up

RJ-11, RJ-41S,

RJ-45S

&J0&W

SW7 down

RJ-12, RJ-13

&J1&W

Command recognition

SW8 down

Enabled

Internal jumper set to

Command

Recognition

Communications standard at
1200 bps

SW9 up

Bell 212A

B1&W

Response to DTR transition
(when SW1 is up)

SW10 up

Hangs up and goes to

command state

Set by SW1 option

NOTE 1. Factory position indicated by boldface.

NOTE 2. Position of SW7 depends on the type of phone jack used. Most installations use an RJ-11 jack (SW7 up).

Parameter

Smartmodem

1200

Switch Position

Option

Smartmodem 2400 AT

Command