Verilink Access Manager 2000 (896-502037-001) Product Manual User Manual
Page 146

Configuring the T1 Network
5-22
Access Manager 2000 User Manual
■
ComDesign: The node’s network management port connects to a
statistical multiplexer.
■
X.25 PAD: The node’s network management port connects to an
X.25 PAD (Packet Assembler Disassembler).
Table 5-5
Node configuration options for older equipment
This includes the for 551VST List 1, 551VST List 1/A, 551VST List 1/B, and 551VST ML List 1. These equipment types
use TABS Protocol and do not support alarm reporting.
Table 5-6
Node Configuration Option for newer equipment
This includes the 551VST (ML) List 2, SIM, NC/E, ConnecT1 Plus, and AS2000. These equipment types use OSI
protocol. The X.25 PAD can only be used with AS2000 equipment.
Access Arrangement (Connection)
Option
Direct
Modem
None
(Facility Data Link
or Daisy Chain)
ComDesign
Baud Rate (Note 1)
1200
1200
1200
120
Query Path
COM 1-16
Phone No.
None
Port Name
Enable Alarm Reporting
No
No
No
No
NOTE 1. Currently, a modem (Comline) configured for 2400 baud cannot initiate calls to a node configured for
1200 baud. Configure the node in Access Manage for 2400 baud, and allow the modem to automatically
downgrade to 1200 baud.
Access Arrangement
(Connection) Option
Direct
Modem
None
(Facility Data Link
or Daisy Chain)
ComDesign
or
X.25 PAD
Report alarms:
Baud Rate (Note 1)
9600
1200/2400
1200/9600
9600
Query Path
COM 1-16
Phone No.
None
Port Name
Alarm Path
COM 1-16
Phone No.
None
Access Manager Port
Name
Previous Node in Chain
(Note 2, 3
Node Name
None
None
None
Enable Alarm Reporting
Yes
Yes
No
Yes
Do not report alarms:
Alarm Path
None
None
None
None