CAUTION
The 4016 List 1 CSU circuit elements can be soft-configured using
Access Manager. However, service interruption may occur if the soft
option settings do not agree with the hardware switches on the 4016
List 1 printed circuit boards. This occurs only when the 4016 List 1
recovers from a power failure and reconfigures itself according to the
hardware switch settings. Therefore, you should configure all 4016
List 1 CSUs so that the hardware switch settings on the CSU agree
with the soft options you choose in Access Manager.