Configuring the T1 Network

5-4

Access Manager 2000 User Manual

Figure 5-4

551VST ML List 2 node

The 551VST ML List 2 node includes the old List 1 or new List 2 shelf with a List 2
controller and Phase IINMC software to permit automatic alarm reporting.

A configuration of one or two stand-alone 551VST MLE expansion
shelves at a location can also be configured as this type of node and
should be configured for Data Link access (i.e., far-end) only.

Some rules of thumb

1. A

551VST List 2 with ASCII interface firmware

is installed as a

55 1VST List 1/B.

2. A 551 VST MLE shelf, equipped with 4016 List 2 CSU modules

and no controller, can only be used as a far end node.

A circuit element is a single module of the parent node to which Access
Manager is connected.

A circuit is the combination of any two network CSU circuit elements
and their interconnecting DS1 facility, which have Access Manager
access in a DS1 network. One endpoint would be a near-end CSU, and the
other would be a far-end CSU.

4016 List 1 or 2 CSUs

14 eac

551VST ML List 2

NMC

List 2

551VST MLB shelf

551VST MLE shelf

(optional)

4016 List 1 or 2 CSUs

14 eac

Circuit element

Circuit