Setups
88
Purge Time
Specifies the time delay from torch ignition until motion is enabled.
Pierce Time
Specifies the time delay from when cutting tool completes lowering until motion is
initiated at Creep Speed. Used to allow the cutting tool to completely pierce the material
before moving.
Creep Time
Specifies the amount of time after piercing the part that the torch travels at Creep Speed.
Creep Speed is determined by a setup parameter at the Speeds setup screen and is a
percentage of the programmed cut speed. After the Creep Time is completed, the control
accelerates to full cut speed.
Abrasive Off Time
The Abrasive Off delay parameter species the amount of time the abrasive will remain on
at the end of a cut.
Abrasive Charging
When selected, the Abrasive Charging feature will charge or fill the abrasive into the
cutting system for use while cutting.