SERCOS Drives Not Enabled and Ready. Please Check Drive are Enabled
and Ready with No Errors.
This status message indicates the SERCOS ring is not running due to a missing enable
signal. First check that the Control Enable Disabled softkey is correct. The softkey
should read DISABLE CONTROL. Then check status of ring hardware or external
drives to ensure there are no errors displayed.
Machine Interface
I/O Configuration Type “V” ( Positive Logic Single Ended I/O )
Connecting single ended I/O to the control. The control provides +24V power on pins
22, 23 & 24 (+24 VDC) and pins 9, 10, 11 &12 (24 VDC Common) on the I/O
connector.
Output tied to external Cut On
Input tied to Cut Sense Relay
Examples of possible circuits
Output
24 VDC
Com