Setups

69

Database Features

Save Process

Pressing the Save Process soft key allows the user to save the current process settings to
the hard drive creating a custom user database based on the eight process variables
selected.

Reset Process

Pressing the Reset Process soft key allows the user to reset the current settings to factory
recommend factory defaults based on the eight process variables selected.

Save Cut Charts

Pressing the Save Cut Charts soft key allows the user to save the current User and
Factory databases to Diskette or USB memory stick. User files are designated with a .usr
file extension and the factory files are designated with a .fac file extension

Examples of user and factory file names.

Mild Steel-Fineline200-Fineline200.usr
Mild Steel- Fineline200-Fineline200.fac

Load Cut Charts

Pressing the load Cut Charts soft key allows the user to the factory default database files
which are supplied by Hypertherm as a user files (.usr) or factory files (.fac) from
Diskette or USB memory stick.
It is recommended that the Database be updated through the control rather than the Power
Supply if the serial communications link is enabled.

Test Preflow

Pressing the Test Preflow soft key performs the Test Preflow Gases feature at the
HD4070

power supply.

Test Cutflow

Pressing the Test Cutflow soft key performs the Test Cutflow Gases feature at the
HD4070

power supply.


Notes:

Please refer to the power supply operators manual for complete information on the
operation and setup of the FineLine Power Supply.

The FineLine Power Supply parameters must first be enabled in the password
protected Station Configuration Screen to allow the Cut Chart Information for the
FineLine to be available for use.

Serial communications for the FineLine Power supply are established on the user
select communication port. The port must be configured for RS-422 operation.