Setups
69
Database Features
Save Process
Pressing the Save Process soft key allows the user to save the current process settings to
the hard drive creating a custom user database based on the eight process variables
selected.
Reset Process
Pressing the Reset Process soft key allows the user to reset the current settings to factory
recommend factory defaults based on the eight process variables selected.
Save Cut Charts
Pressing the Save Cut Charts soft key allows the user to save the current User and
Factory databases to Diskette or USB memory stick. User files are designated with a .usr
file extension and the factory files are designated with a .fac file extension
Examples of user and factory file names.
Mild Steel-Fineline200-Fineline200.usr
Mild Steel- Fineline200-Fineline200.fac
Load Cut Charts
Pressing the load Cut Charts soft key allows the user to the factory default database files
which are supplied by Hypertherm as a user files (.usr) or factory files (.fac) from
Diskette or USB memory stick.
It is recommended that the Database be updated through the control rather than the Power
Supply if the serial communications link is enabled.
Test Preflow
Pressing the Test Preflow soft key performs the Test Preflow Gases feature at the
HD4070
power supply.
Test Cutflow
Pressing the Test Cutflow soft key performs the Test Cutflow Gases feature at the
HD4070
power supply.
Notes:
•
Please refer to the power supply operators manual for complete information on the
operation and setup of the FineLine Power Supply.
•
The FineLine Power Supply parameters must first be enabled in the password
protected Station Configuration Screen to allow the Cut Chart Information for the
FineLine to be available for use.
•
Serial communications for the FineLine Power supply are established on the user
select communication port. The port must be configured for RS-422 operation.