Password Setups
360
Refer to Appendix A for a complete description of
appropriate “M” code commands.
Cut Control
Enables the cutting oxygen in oxy fuel mode or starts the
plasma system in plasma mode. This output can also be
used to activate a marking device.
Low Preheat Control
Enables the low preheat gas when cutting in oxy fuel mode.
It is activated for the “Low Preheat Time” when initiating a
cut.
Preheat Control
Enables the high preheat gas when cutting in oxy fuel
mode. It is activated for the “High Preheat Time” when
initiating a cut.
Key Press Indicator
Activated whenever a key is pressed on the control.
Motion Indicator
Activated whenever the CNC is commanding machine
motion.
Plasma Select
Activated whenever the CNC is in the Plasma cutting
mode.
Bleed Off Gas
Used by the oxy fuel cut logic to send an output to the oxy
torch to purge gases at the end of a cut. This output is on
for the duration of the Bleed Off time selected in setups.
Pierce Control
Used by the plasma and oxy fuel cut logic to send an output
to the torch during the pierce. This output is on for the
duration of the Pierce Time selected in setups.
Turn ON / Off Supply
Used by the Optional APC to turn on or off the plasma
supply through the control.
N2 Select
Used by the Optional APC to enable the use of nitrogen
while cutting.
Drive Enable
Used to enable the drives during normal functions and to
disable the drives during fault conditions.
Fume Extraction Control
Enables fume extraction and the Initial Feedback Delay and
Fume Extraction Delay fields.
Shutter Open
Used exclusively with the laser cut logic to open the laser
shutter for use.