Automated Plasma Interface
499
Outputs
Note: Similar to the standard Output Diagnostic screen, the output screen shows the current status of the
listed supply outputs. Note: Outputs for the supply cannot be activated through the diagnostic screen.
Serial Communication Interface
RS-422C Connections to HPR CNC Interface
Control (male)
Supply (male)
Signal Name
DB-9 Pin
Signal Name
DB-37 Pin
TxD- 2 RxD- 1
RxD- 3
TxD- 2
TxD+ 4 RxD+
20
RxD+ 7 TxD+
21
RS-422C Connections to HD4070 CNC Interface
Control (male)
Supply (male)
Signal Name
DB-9 Pin
Signal Name
DB-37 Pin
TxD- 2 RxD- 2
RxD- 3
TxD- 1
TxD+ 4 RxD+
21
RxD+ 7 TxD+
20