Hypertherm Phoenix 8.0 User Manual
Page 368
Password Setups
361
Assist Gas
Used exclusively with the laser cut logic to activate the
assist gas.
Digital Beam
Used exclusively with the laser cut logic to activate the
digital beam.
Laser Start
Used exclusively with the laser cut logic to activate the
laser system.
Abrasive Control
Used exclusively with water jet cut logic and activates the
abrasive control, adding abrasive to the cut stream while
cutting, or for charging the abrasive prior to cutting.
Plasma Enables
Used for external logic. The appropriate output(s) is on
during plasma cutting, based on the Plasma Select inputs.
Marker Enables
Used for external logic. The appropriate output(s) is on
during marking, based on the Marker Select inputs.
Nozzle Contact Enable
Active during Sensor THC IHS. This input is tied back to
the CNC through the external voltage divider card. This
output can also be used to switch an external drive system
to low output mode (if equipped) during IHS for stall force
plate sensing.
Hold Ignition
Is part of the Sensor THC operation to hold ignition of the
external Plasma Supply. This output can be tied back to the
CNC through the external voltage divider card or direct to
the power supply depending on configuration.
Gas Flow Set 1 – 100
Used as part of the HD3070 automatic gas console
communications (BCD) to set gas flow rates.
Valve Select 1 – 8
Used as part of the HD3070 automatic gas console
communications to select the appropriate valves for
operation.
Gas Control Write
Used as part of the HD3070 automatic gas console
communications to configure the unit for operation.
Remote Test Operate
Used as part of the HD3070 automatic gas console
communications to initiate the remote test.
Remote Test Preflow
Used as part of the HD3070
automatic gas console
communications to test operation of preflow gases.