Hypertherm Phoenix 8.0 User Manual
Page 79
Setups
72
Press the Timing Diagram soft key to view the timing diagram from setups.
Ignition Time
(Ignition Output) Specifies the length of time that the ignition output is held on at each
ignition point.
Marker On Time
(Time Delay) This parameter allows the operator to insert a time delay, which allows the
marker to prepare for operation prior to the start of Marker motion.
Marker Off Time
(Time Delay) This parameter allows the operator to insert a time delay, which allows the
marker to prepare for operation prior to the end of Marker motion.
Marker Up Time
(Torch Up Output) Specifies the length of time to raise the marker at the beginning and
end of each mark.
Marker Partial Up Time
(Torch Up Output) Specifies the length of time for partial raise of the marker at the
beginning and end of each mark. Note: The Partial Raise parameter must be enabled.