574

The Mariner Shape Cutting Control is designed with all machine interface connections
passing through the pedestal mount at the base of the enclosure. Motion and I/O are
supported via the fiber optic communication ring of the SERCOS Interface.

The information contained in this section is intended to provide the basic information for
connection of the Mariner Shape Cutting Control to the cutting table. Each machine
interface will vary slightly based on the cutting table configuration and features.

AC Input Pinout

TB connector

Description

101

110VAC or 220VAC Input (Hot)

102

110VAC or 220VAC Input (Neutral)

AC Power Ground

Recommended Wire

14 AWG or greater

E-Stop

The E-stop Switch provides normally open contacts rated at 20VAC/500mA minimum to
250VAC/6A maximum.

TB connector

Description

103 Contact

Closure

104 Contact

Closure

Diagram Location Din-02

SERCOS Motion and I/O

As noted previously, Motion and I/O are supported via the fiber optic communication
ring of the SERCOS Interface. Digital and Analog I/O are supported.