Ac input pinout, E-stop, Diagram location din-02 – Hypertherm Phoenix 8.0 User Manual
Page 581: Sercos motion and i/o
Mariner
574
The Mariner Shape Cutting Control is designed with all machine interface connections
passing through the pedestal mount at the base of the enclosure. Motion and I/O are
supported via the fiber optic communication ring of the SERCOS Interface.
The information contained in this section is intended to provide the basic information for
connection of the Mariner Shape Cutting Control to the cutting table. Each machine
interface will vary slightly based on the cutting table configuration and features.
AC Input Pinout
TB connector
Description
101
110VAC or 220VAC Input (Hot)
102
110VAC or 220VAC Input (Neutral)
AC Power Ground
Recommended Wire
14 AWG or greater
E-Stop
The E-stop Switch provides normally open contacts rated at 20VAC/500mA minimum to
250VAC/6A maximum.
TB connector
Description
103 Contact
Closure
104 Contact
Closure
Diagram Location Din-02
SERCOS Motion and I/O
As noted previously, Motion and I/O are supported via the fiber optic communication
ring of the SERCOS Interface. Digital and Analog I/O are supported.