Station selects – Hypertherm Phoenix 8.0 User Manual
Page 471
Program Codes
464
4B
Station Selects
Stations (Lifter / THCs) may be selected and de-selected using a EIA-274D program code with
the following format.
75B
75B 75B
75B
CODE
DESCRIPTION
M19 Tvalue
Cancel All Station Selections
M37 Tvalue
Select Station 1-20 (Tvalue)
M38 Tvalue
De-Select Station 1-20 (Tvalue)
Additionally, these Station Select program codes may be overridden using the user selected
THC inputs to the control. The feature to override the part program must be enabled at the
Cutting Setup screen.
20B
Process Selects
Process Selections may be selected using a EIA-274D program code with the following format.
Example:
UUU
M36
UUU
UUU
Tvalue
UUU
54B
Misc. M Code
55B
Valve Identity
T1 = Plasma Process 1
T2 = Plasma Process 2
T3 = Marker Process 1
T4 = Marker Process 2
T5 = Laser Process
21B
Station Configuration Variables
The following options are available for the station configuration
22B
Lifter
None
Sensor THC
Command THC (w/ Serial Link)
HD4070 Integrated THC 1 or 2 (used only with the HD4070 power supply)
Other (any stand alone Lifter Station)
23B
Power Supplies
None
HD4070 Torch 1or 2 Powermax series
Max100/ 100D
HT4001
FineLine 100
Max200
HT4100
FineLine 200
HT2000
HT4400
Other (any other Plasma system)
HD3070
HPR130
24B
Marker
None
ArcWriter
FineLine 100 & 200
HD4070 Torch 1or 2
HPR130
Other (any stand alone Marker)