Setups screen – Hypertherm Phoenix 8.0 User Manual
Page 37
Overview
29
and retain the part and current position information. This then allows the user to load and
execute another part program and return to the original part using the Resume Last Part soft
key.
Note: Controllers with SERCOS interface will save position information every minute to the
hard drive. Some motion on path may be required for power or position loss recovery.
Show Certain Files
This soft key allows the operator to show only certain files from the selected directory. Both
the asterisk and question mark may be used in defining the files to show.
Keypad operation: The asterisk is generated by holding down the left shift key and pressing the
backspace key. The question mark is generated by holding down the right shift key and
pressing the backspace key.
Show All Files
This soft key allows the operator to undo the Show Certain Files from above.
Note: An optional Network Card for connecting directly to a PC Network for part file
allocation is available.
Setups Screen
The Setups Screen is used to configure the control.
Cutting
Allows programming of the different cutting parameters and dwell times.
Process
Enters the cut type menu, which allows editing of gas control sequencing variables for oxy-fuel
and plasma cutting.
Disable Control
Pressing the Disable Control soft key disables the motion command from the control to the
drive system. While disabled, I/O points and encoder feedback are still active.
Watch
Allows programming of the user definable Watch Window.
Password
Enter a password to get to the supervisor password protected setup menu.
Diagnostics
Opens the diagnostics menu.
Change to Metric Units/English Units
Changes all parameters over to metric units or English units.