Hypertherm Phoenix 8.0 User Manual
Page 517
Automated Plasma Interface
510
Pressing the Reset Process soft key allows the user to reset the current settings to factory recommend
factory defaults based on the eight process variables selected.
Save Cut Charts
Pressing the Save Cut Charts soft key allows the user to save the current User and Factory databases to
Diskette or USB memory stick. User files are designated with a .usr file extension and the factory files
are designated with a .fac file extension
Examples of user and factory file names.
Mild Steel-Fineline200-Fineline200.usr
Mild Steel- Fineline200-Fineline200.fac
Load Cut Charts
Pressing the load Cut Charts soft key allows the user to the factory default database files which are
supplied by Hypertherm as a user files (.usr) or factory files (.fac) from Diskette or USB memory stick.
It is recommended that the Database be updated through the control rather than the Power Supply if the
serial communications link is enabled.
Test Preflow
Pressing the Test Preflow soft key performs the Test Preflow Gases feature at the HD4070
Power
supply.
Test Cutflow
Pressing the Test Cutflow soft key performs the Test Cutflow Gases feature at the HD4070
Power
supply.
Notes:
• Refer to the power supply operator’s manual for complete information on the operation and setup of
the FineLine Power Supply.
• The FineLine Power Supply parameters must first be enabled in the password protected Station
Configuration Screen to allow the Cut Chart Information for the FineLine to be available for use.
• Serial communications for the FineLine Power supply are established on the user select
communication port. The port must be configured for RS-422 operation.