Hypertherm Phoenix 8.0 User Manual
Page 57
Setups
50
3.
When you finish selecting controls and assigning outputs, press or click OK.
When you return to the Oxy Fuel screen, the parameters for the control you selected
are added to the screen.
4.
Edit the values for the parameters to meet the needs of your process.
Oxy Torch Pressures
Select the type of oxy fuel torch for the process.
Oxy Cut Pressure
Enter the pressure, in pounds per square inch, of the oxy fuel during cutting.
Oxy Ramp Up Time
Enter the time, in seconds, that the oxy fuel takes to reach cutting pressure.
Preheat Low Pressure
Enter the pressure, in pounds per square inch, of the oxy fuel at low pressure during
preheat.
Preheat High Pressure
Enter the pressure, in pounds per square inch, of the oxy fuel at high pressure during
preheat.
Preheat Pressure
Enter the preheat pressure, in pounds per square inch, for the triple bevel head.
Preheat Ramp Up Time
Enter the number of seconds that the process takes to move from low to high pressure
during preheat.
Preheat Ramp Down Time
Enter the number of second that the process takes to move from high to low pressure
during preheat.
Fuel Low Pressure
Enter the pressure, in pounds per square inch, of the oxy fuel at low pressure during
cutting.
Fuel High Pressure
Enter the pressure, in pounds per square inch, of the oxy fuel at high pressure during
cutting.
Fuel Pressure
Enter the fuel pressure, in pounds per square inch, for the triple bevel head.
Fuel Ramp Up Time