Hypertherm Phoenix 8.0 User Manual
Page 484
Program Codes
477
The following parameters must be configured. Hardware and flow control configuration
information must match the external device.
34B
Baud Rate
Select a communication speed from 1200 Baud to 115200 Baud
35B
Parity
Select None, Odd or Even.
36B
Data Bits
Select 7 or 8 Data Bits.
37B
Flow Control
Select to use None, Xon/Xoff or Hardware.
38B
During Jog on Path
The user may select whether messages will be sent when jogging Forward or Backward on Path
while at the Pause screen. Note: All messaging will stop when the Stop Key has been pressed
or the Remote Pause input becomes active.
Note: The Message Type 21 will transmit the message concurrent to the associated motion
segment during “Backup on Path”.
39B
Retry on Time Out
For the Message Type 22 (which requires an acknowledgement from the external device after
the message) an automatic retransmit of the message may be sent. The user may select the
number of retries allowed before faulting from a lack of response from the external device. The
fault prompt “Message Error” will be displayed when in a Time Out condition.
40B
Time Out
The Time Out value may be used for the Message Type 22 (which requires an
acknowledgement from the external device after the message) if there is no Time Out value
used in the command string of the program code. Refer to the Delay Time / Time Out
information for more information.
41B
Programming Code
The ASCII message string follows a unique program message format. Each command begins
with a “>” character and ends with a “<” character. These characters are used as delimiters to
frame the command (Message Type, Optional Format and Optional Delay Time/ Time Out)
instructions for the message.