DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol

SNMP (MIB)

MN-DMDREMOTEOP Revision 9

2–3


RadVoltageLevel ::= TEXTUAL-CONVENTION
DISPLAY-HINT "d-1"
STATUS current
DESCRIPTION "Voltage level in tenths of a volt."
SYNTAX INTEGER (0..550)

RadCurrentLevel ::= TEXTUAL-CONVENTION
DISPLAY-HINT "d-3"
STATUS current
DESCRIPTION "Current level in milliamps."
SYNTAX INTEGER (0..8000)

ControlType ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION "Represents a boolean control value."
SYNTAX INTEGER { disable(1), enable(2) }

OffOnType ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION "Represents a boolean Off/ON control value."
SYNTAX INTEGER { off(1), on(2) }

InversionType ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION "Represents a boolean inversion value."
SYNTAX INTEGER { normal(1), inverted(2) }

BerStatusStringType ::= TEXTUAL-CONVENTION
DISPLAY-HINT "8a"
STATUS current
DESCRIPTION "Raw BER status"
SYNTAX OCTET STRING (SIZE (10))

CarrierSweepDelayType ::= TEXTUAL-CONVENTION
DISPLAY-HINT "d-1"
STATUS current
DESCRIPTION "Sets the carrier sweep delay in secs. There is one implied decimal point.
A value of 215 corresponds to a 21.5 sec sweep delay."
SYNTAX INTEGER (0..65535)

TimeConstantType ::= TEXTUAL-CONVENTION
DISPLAY-HINT "d-1"
STATUS current
DESCRIPTION "Sets time constants in mSecs for feedback or error accumulators. There is
one implied decimal point.
A value of 1000 corresponds to a 1.000 sec time constant"
SYNTAX INTEGER (0..65535)

EbnoType ::= TEXTUAL-CONVENTION
DISPLAY-HINT "d-2"
STATUS current
DESCRIPTION "EbNo in db. There is an implied decimal point."
SYNTAX INTEGER (0..2500)

EbnoAlarmThresholdType ::= TEXTUAL-CONVENTION